Large school roof after renovation with a white 2K polyurea waterproofing

PS-PUA-01 / Engineered System

PolyShield Roof Renew

Premium renovation membrane for commercial roofs

From a stable existing roof membrane to a seamless, verifiable 2K renovation system.

What this system was developed for

A clear project role, not a universal coating.

APPLICATION

Commercial roofs

Education and healthcare real estate

Logistics buildings

Planned lifespan extension

SUBSTRATE

Stable mineral bitumen

Concrete

Cement-bound slope layer

PROJECT VALUE

Renovation without complete demolition where the structure is suitable

Applied cold and without open flame

Early weather resistance within the right conditions

Documentable system and consumption route

DIRECT TECHNISCH ANTWOORD / PS-PUA-01

When is this route promising?

Cold-applied 2K polyurea is especially promising for an existing commercial roof if roofing membranes and insulation are sufficiently stable and dry, details remain repairable and adhesion can be demonstrated with a project-specific primer.

PS-PUA-01 / interactive system build-up

See what every system layer does.

Separate the layers, select a function and see which control point and project evidence belong to the next work phase. This visual is a technical selection framework, not a universal installation detail.

Illustrative system build-up.The final primer, layer thickness, reinforcement, finish and application follow from substrate assessment and current technical documentation.

Complete system construction

Each layer has one controllable function.

The structure shown is a selection frame. Primer, layer thickness, consumption and details are only finalized after inspection, test surface and document check.

LOW 01

Controlled surface

Determine moisture, adhesion, slope and repairability

LOW 02

Surface-specific primer

Organize adhesion and pore control

LOW 03

Armored details

Reinforce seams, bilges, drains and transitions

LOW 04

2K-polyurea membraan

Seamless exposed waterproofing

Technical gate

Check first.

01Moisture status insulation

02Stability of existing jobs

03Trial bonding

04Details and water drainage

05Desired operating time

System Passport

This must remain demonstrable after implementation.

01

ETA/DoP en actuele TDS per gekozen variant

02

Surface and moisture registration

03

Consumption per work area

04

Photo and delivery file

Executed project proof

PolyShield Roof Renew in aantoonbare projectsituaties.

These files make visible which scope has actually been covered. A reference proves experience, but never replaces inspection and system selection for a new building.

Planmatige renovatie schooldak in Nederland · locatie vertrouwelijk
PSP-RR-001 · complete scope

Planned renovation of school roof

Approximately 700 m² · Netherlands · location confidential

Open technical project file ↗
Risicogericht dakherstel boven productie in Middelburg, Nederland
PSP-RR-002 · local scope

Risk-oriented roof repair over production

Approximately 150 m² treated · Middelburg, Netherlands

Open technical project file ↗
Lokale 2K-dakrenovatie bedrijfspand in Den Haag, Nederland
PSP-RR-003 · local scope

Local 2K roof renovation commercial property

Approximately 350 m² total roof · The Hague, Netherlands

Open technical project file ↗
Verouderd lekkagegevoelig bedrijfsdak in Aalsmeer vóór renovatieVóórNa

Eigen projectbewijs

PS / TRANSFORMATION 02 · Aalsmeer · Circa 700 m²

Van lekkagegevoelig dak naar een samenhangend renovatievlak.

Een bestaand bedrijfsdak laat zien waarom Roof Renew begint bij ondergrond, naden en kritieke zones.

Ondergrond
Bestaande dakbedekking
Resultaat
Een samenhangend waterdicht renovatievlak met een lichte, onderhoudbare eindafwerking.

Frequently asked technical questions

Short answer, clear line of evidence.

Can this system be used directly over existing bitumen?+

Not without assessment. Cleanability, stability, moisture, chipping, blistering, repairs and test adhesion determine the preparation and primer route.

Does the entire roof need to be fully reinforced?+

Not always. Local detail reinforcement and full reinforcement are different routes. The current system documentation and expected movement determine the choice.

Is an expected useful life automatically a guarantee?+

No. A technical service life category belongs to a described system scope and is not an unconditional project guarantee.

Technical floor

Lees verder op de vragen die voor deze opbouw beslissend zijn.

Renovation decision

Coating the roof or replacing it completely?

Conservation is especially promising when the existing structure is stable, dry and repairable.

Lees technisch antwoord ↗
Attachment

Why a primer is not an afterthought

The primer function depends on the substrate, porosity, moisture and the chosen membrane technology.

Lees technisch antwoord ↗
Layer thickness

How consumption becomes controllable

Optical coverage is not proof of layer thickness; material quantity is linked to work area and surface.

Lees technisch antwoord ↗