Technical Evidence Center

From certificate to applicable project evidence.

We make visible what a document actually proves, to which system structure it applies and which project-specific checks are still required.

Terminology

ETAG was the guideline. ETA is the product-specific rating.

ETAG 005 was the former European assessment guideline for liquid-applied roof waterproofing kits. The current route uses European Assessment Documents. For this product family, ETAG 005 has been replaced by EAD 030350-00-0402.

A manufacturer can obtain an ETA based on an applicable EAD. The ETA describes the intended use and assessed performance. The associated performance declaration and CE marking do not mean that any roof construction is automatically suitable.

Technical proof

Performance is system and structure specific.

The statuses below are deliberately reserved. A proof is only shown as proven after the current document, the system variant and the intended use have been checked.

To be verified on a project basis

ETA/EAD

An ETA applies to the described system kit and its intended use. Document number and current system variant are checked before publication.

To be verified on a project basis

CE and declaration of performance

CE and DoP describe declared product performance; they are not a blanket endorsement of every roofing project.

Construction-related

BROOF classification

Only claimable for the exact tested roof structure, substrate, layer thickness and the stated test suffix, for example BROOF(t1).

To be verified on a project basis

Waterproofing

Test performance and application conditions must correspond to the selected membrane variant and project structure.

To be verified on a project basis

Crack bridging and movement

Class, temperature and layer thickness are taken from the current technical documentation.

To be verified on a project basis

VOC and environmental documentation

VOC, EPD and other environmental claims are only published with a current, traceable source.

Conceptual framework

Five documents and concepts that should not be mixed up.

EAD
European Assessment Document: the European assessment method for a product family or innovative product.
ETA
European Technical Assessment: product-specific assessment with performance and intended use.
DoP
Declaration of Performance: the manufacturer's declaration of performance for the construction product in question.
BROOF(t1)
Classification for external fire performance of a specifically tested roof structure according to test method t1.
Project proof
Registration of what has been examined, processed, checked and delivered on the concrete object.

Chain of custody

This links evidence to an actual roof.

  1. 01

    Identify product

    Record exact commercial variant, components and intended use; similar products are not automatically interchangeable.

  2. 02

    Check source

    Link current ETA, EAD, DoP, CE information, classification report, TDS and SDS to the same variant.

  3. 03

    Limit build-up

    Compare the substrate, primer, reinforcement, consumption, layer thickness, finish and any protective layers with the evidence.

  4. 04

    Project assessment

    Assess existing roof, national requirements, fire safety, use, details and implementation conditions on a project-specific basis.

  5. 05

    Register execution

    Record materials, conditions, consumption, details, photos, deviations and delivery points in the project passport.

External fire performance

BROOF belongs to a roof structure, not just to a bucket.

A classification is stated with the appropriate test suffix, for example BROOF(t1). Substrate, carrier, insulation, existing roof covering, primer, membrane, layer thickness and finish can be part of the classification limit.

  • Exact classification report and valid variant
  • Tested surface and complete layer build-up
  • Layer thickness, consumption and possible color limitations
  • Test method and suffix t1, t2, t3 or t4
  • Project requirements and national application