PolyShield Systems · Netherlands & Belgium
POLYSHIELDSYSTEMSRequest project
Menu
What would you like to solve?
Waterproofing systems
Spray application
Solutions
Products
Floor systems
Projects Knowledge base Services Request project
Planned roof renovation of school building in Location confidential

Project file 03

Planned roof renovation of school building

Location confidential, Netherlands · Complete cold applied 2K polyurea system

Project image

Which is demonstrable in this project.

Approximately 700 m² of outdated bituminous roofing with strong crackle formation, systematically renovated with primer, reinforced details and two layers of white 2K polyurea.

The content is based on available implementation information and project images. For a new object, the surface, load, details and system choice are always determined project-specifically.
ObjectSchool building
SizeApproximately 700 m²
SubstrateExisting bitumen
Damage pictureStrong crackle formation
SystemPrimer, geotextile and 2K polyurea
Project goalPlanned lifespan extension

Interactive Project Evidence

From the initial condition to a
verifiable result.

Review the work sequence by phase. Images gain technical value only when their content and project boundaries are clear.

Initial situation at Planned roof renovation of school building Location confidential01 / Initial situationPROJECT EVIDENCE
VISUAL COMPARISONBefore / latest available project phase
Initial condition of Planned roof renovation of school building
Latest available phase of Planned roof renovation of school building
START / Initial situationLATEST PHASE / Final check

POLYSHIELD PROOF TWIN / SCHOOLDAK

See what happens beneath the white final surface.

Based on our own project images

The project images connect the documented condition, execution phases and visible result without filling in missing data.

Circa 700 m²roof area
Bestaand bitumensubstrate
2K-polyureamembrane technology
Zes fasendocumented
Initial condition — See what happens beneath the white final surface.
01 / Initial conditionDIGITAL PROJECT MODEL

Technical demarcation

A conservation strategy tailored to the remaining building function.

There were no active leaks, but the aging required timely intervention. Because the building is expected to remain functional for another fifteen years, a practical system renovation was opted for rather than complete replacement. The white finish also supports the goal of limiting solar absorption.

01 / Challenge

The technical task

The existing bituminous roof covering was very outdated and showed a lot of crazing. There were no active leaks, but the roof practically needed to be preserved for the remaining period of use of the school building. In addition, limiting summer heat loads was an important project goal.

02 / Approach

The system-oriented method

  1. 01Clean the entire roof surface under high pressure and make it suitable for further treatment
  2. 02Provide the dry bituminous surface with a quick-drying PU primer
  3. 03Reinforce transitions, seams and critical connections with 60 gram geotextile
  4. 04Apply two layers of cold-applied 2K polyurea with a total consumption of approximately 2 kg per m²
  5. 05Visually check the white, UV-resistant end surface and all connections
03 / Result

The visible result

The outdated bitumen roof has been preserved as a coherent system and provided with a light, seamless and UV-resistant waterproofing. The white finish absorbs less solar heat than the original dark roof, thus supporting the goal of limiting the building's summer heat load.

Decision factors

Why this scope made technical sense.

A system name alone does not explain project choice. The existing condition, risks, details and feasibility together determine the renovation strategy.

01

Project decision

  • Strongly aged bitumen without active leakage
  • Remaining period of use of the building
  • Limiting major demolition work
  • Wish for a light, UV-resistant final layer
02

Included in the scope

  • Complete high-pressure cleaning
  • Fast drying PU primer
  • 60 gram geotextile on transitions
  • Two layers of 2K polyurea, total approximately 2 kg/m²
03

Technically assessed

  • Stability of the existing bituminous subsurface
  • Crackle, seams, upstands and penetrations
  • Dryness before primer and membrane
  • Connection of system choice to usage horizon

Execution in pictures

Six controllable steps.

From existing bituminous roofing to a completely white waterproofing system.

Initial situation during planned roof renovation of a school building in Location confidential
01 / Werkfase

Initial situation

Aged bitumen with extensive crazing, without active leakage.

Cleaning during planned roof renovation of a school building in Location confidential
02 / Werkfase

Cleaning

The entire roof surface has been thoroughly cleaned under high pressure.

Primer for planned roof renovation of school building in Location confidential
03 / Werkfase

Primer

The prepared surface is provided with a quick-drying PU primer.

Reinforced details of planned roof renovation of school building in Location confidential
04 / Werkfase

Armored details

Transitions and critical connections are reinforced with 60 gram geotextile.

2K membrane for planned roof renovation of a school building in Location confidential
05 / Werkfase

2K membrane

Two layers of cold-applied 2K polyurea form the white UV-resistant waterproofing.

Final inspection during planned roof renovation of school building in Location confidential
06 / Werkfase

Final check

Roof surface, curbs, penetrations and details are checked as one system.

Project result

Lifespan extended. Heat load limited.

The light roof finish absorbs less solar heat than the original dark bitumen. The exact influence on the indoor temperature also depends on insulation, ventilation, use and weather conditions.

  • 01Practical conservation without complete replacement of the existing roof structure
  • 02Seamless waterproofing over surfaces, seams, curbs and penetrations
  • 03White UV-resistant finish with lower solar absorption than the dark bitumen
  • 04Project scope tailored to the remaining use period of the building

Quality & evidence limit

What has been checked, confirmed and deliberately not generalized?

Control

Quality moments

  • Visual inspection after cleaning
  • Primer continuity before follow-up coat
  • Complete embedding of geotextiles
  • Final check of surface, details and elevations
Evidence

Confirmed project information

  • All six implementation phases were photographically recorded
  • Area and material consumption are available as project data
  • System structure is described from cleaning to final inspection
  • White final finish has been visibly delivered
Border

Project-specific boundaries

  • No independent indoor temperature measurement has been carried out
  • Lower solar absorption is not the same as a guaranteed temperature reduction
  • New projects require moisture, adhesion and detail assessment again
Technical project passport

System variant, substrate, primer, batch data, consumption, application conditions, ETA/DoP, applicable BROOF build-up and maintenance are only included when confirmed project-specifically.

View the evidence and documentation method →

PolyShield System Passport

From system name to demonstrable project structure.

PSP-RR-001PS-PUA-01Executed and photographically recorded
Planmatige renovatie schooldak, projectbewijs voor PS-PUA-01Complete roof scope
Project
Planned renovation of school roof
Location
Netherlands · location confidential
Size
Approximately 700 m²
Substrate
Existing bituminous roofing
AANLEIDING

Strong crackle formation, residual building function and desire to limit solar absorption.

01

Preparation

  • Complete high-pressure cleaning
  • Visual surface check
  • Fast drying PU primer
02

System construction

  • 60 gram geotextile on transitions
  • Two layers of cold applied 2K polyurea
  • Total consumption approximately 2 kg / m²
  • White UV resistant final finish
03

Checkpoints

  • Primer continuity
  • Embedding geotextiles
  • Roof surface, upstands and penetrations
  • Photo file of six work phases
RECORDED RESULT

The existing roof has been preserved as a coherent system and lightly finished without replacing the entire roof structure.

BEWIJSGRENS

No independent indoor temperature measurement has been carried out. The influence on the indoor climate remains building-specific.

View associated system family

Van projectbeeld naar controleerbaar bewijs

Een projectdossier moet meer laten zien dan alleen het eindresultaat.

PolyShield bouwt projectbewijs op rond zes vaste onderdelen: uitgangssituatie, technische keuze, systeemopbouw, uitvoering, kwaliteitscontrole en oplevering. Zo blijft zichtbaar wat daadwerkelijk is uitgevoerd en welke gegevens projectspecifiek zijn.

PolyShield Project Evidence
  • Voor-, tijdens- en na-beelden met functie
  • Bevestigde ondergrond en behandelde zones
  • Relevante systeem- en controlegegevens
  • Open benoemde bewijsgrenzen
Bekijk onze projectbewijsmethode →

NEXT STEP

Want to extend the lifespan without immediately replacing the entire roof?

A conservation renovation starts with the question of whether the existing structure is technically suitable. We collect the first project data for that assessment via Roof Intelligence.

Start technical screening Measure the roof areaConsult first →