PS-PUA-02 / Engineered System
PolyShield Cool Roof
White reflective 2K roof renovationWaterproofing, UV exposure and solar reflectance combined in one technically specified roofing system.

PS-PUA-02 / Engineered System
Waterproofing, UV exposure and solar reflectance combined in one technically specified roofing system.
What this system was developed for
Warm production halls
Logistics real estate
Commercial roofs with high sun exposure
Buildings with cooling demand
Suitable existing roof covering
Concrete
Metal with appropriate corrosion route
White waterproof final coat
High UV and weather resistance
Can help limit surface temperature
No unfounded energy saving promise
A technical Cool Roof is first a waterproof roof system and only then a white finish. Reflection values, pollution, insulation, building use and the complete roof structure determine whether and how much thermal benefit is achievable.
PS-PUA-02 / interactive system build-up
Separate the layers, select a function and see which control point and project evidence belong to the next work phase. This visual is a technical selection framework, not a universal installation detail.
Complete system construction
The structure shown is a selection frame. Primer, layer thickness, consumption and details are only finalized after inspection, test surface and document check.
Combining thermal context and roof condition
Record surface and detailed route
Seamless reflective membrane layer
Reflection, contamination and details monitor periodically
Technical gate
01Reflectance values per color
02Insulation and building use
03Pollution tax
04Ventilation and cooling
05Fire classification of the complete structure
System Passport
Current reflection and SRI documentation
Roof structure and fire report
Temperature or energy baseline measurement if relevant
Maintenance advice
Project evidence under construction
Until then, we will not show a generic or borrowed project claim. Share your project situation for a project-specific assessment.
Have a project assessed ↗Frequently asked technical questions
No. A white surface can limit sun absorption, but the building savings depend, among other things, on insulation, ventilation, cooling, use and maintenance.
No. Chemistry, primer, layer thickness, mechanical properties, water load, reflection and documentation can vary greatly.
Pollution and aging affect reflection. Cleanability, maintenance and, where available, outdated values are part of the assessment
Technical floor
Technology comparisonCompare complete builds by substrate, primer, details, use and evidence — not just white color.
Lees technisch antwoord ↗
Fire performanceBROOF applies to a documented, tested roof build-up and not automatically to a standalone coating name.
Lees technisch antwoord ↗
FileTDS, SDS, DoP, ETA and reports must be linked to the actually applied project structure.
Lees technisch antwoord ↗